SURE-Pulse Demonstration

A tutorial video on relinc.net/software uses these files to run the tutorial.

This folder contains all the necessary files and information to create three compression samples in the SURE-Pulse software. 

All of the samples have their own folder with data and dimensions.

General Information:
Sample Material: 7075T6 Aluminum
C300 Maraging Steel Bars

The bar setup used for these samples is laid out below.

Strain Gauge: (Used by both bars)
Resistance: 120.0 Ohm
Length: 0.25
Voltage Calibrated: 0.0055 V
Gauge Factor: 2.14
Shunt Resistance: 59.94 kOhm

Incident Bar:
Density: 0.298 lb/in^3
Diameter: 0.5 inches
Yield: 300.0 ksi
Young’s Modulus: 29.3165 psi * 10^6
Speed Limit: (calculated)
Length: 72.0 inches
Strain Gauge: 36 inches to sample

Transmission Bar:
Density: 0.298 lb/in^3
Diameter: 0.5 inches
Yield: 300.0 ksi
Young’s Modulus: 29.3225 psi * 10^6
Speed Limit: (calculated)
Length: 72.0 inches
Strain Gauge: 36 inches to sample